撰稿:lzk更新日期:2020-10-21

On February 28th, 2006, the Administration Measure for the Control of Pollution for Electronic Information Products was published. In order to reduce the pollution to the environment.,the measure regulates the disassembly and treatment after the electronic information products are disposed, this measure is also called “China RoHS”. The measure came into force on March 1st, 2007.
 
Based on the Type Classification of Electronic Information Products, eleven categories of electronic information products are applicable, including electronic communication equipments, broadcast television equipments, computers, home electronic products etc. Microwave oven and induction cooker belong to the home electronic and appliance in the 10th category of electronic application products.
 
Currently, 43 related voluntary standards have been published, which include GB/Z 20288-2006, GB/Z 21274 to GB/Z 21277, GB/T 23690, GB/T 26125, GB/T 26572, SJ/T 11364-2006, SN/T 2000 to SN/T 2005SN/T 2591 to SN/T 2593, and SN/T 3019. These standards involve in testing methods, disassembly, labeling and material declaration. Enterprises can test the products according to GB/T 26125-2011 (testing methods), make the judgment compared to the concentration limits specified in GB/T 26572-2011, and make the self-declaration according to SJ/T 11364-2006.
 
According to the rule, microwave oven and induction cooker should bear the pollution control mark for electronic information products. For products which concentration of hazardous substance is lower than the specified limit, “green label” is affixed. For products which concentration of hazardous substance is higher than the limit, “orange label” is affixed. In this case, the name, concentration of the hazardous substance and the parts that they exist should be provided in the product instructions. The regulated hazardous substances and the limits are similar to EU RoHS.
   
Recently, the Administration Measure for the Control of Pollution for Electronic Information Products is being revised, which name is changed to the Administration Measure for the Control of Pollution for Electronic and Electrical Products. The regulated scope is going to expand from the electronic information products to all the electronic and electrical products, which the rated voltage is below 1500 V D.C. or 1000 V A.C. The consultant draft of this revised measure has just been circulated and is going to notify to WTO members.
 
Standard Number
Standard Name
GB/Z 20288-2006
General disassembly requirements for testing hazardous substances in electrical and electronic products
GB/Z 21274-2007
Determination of regulated substances (lead, mercury and cadmium)in electrical and electronic equipment
GB/Z 21275-2007
Determination of regulated substance (hexavalent chromium)in electrical and electronic equipment
GB/Z 21276-2007
Determination of restricted substances (polybrominated biphenyls and polybrominated diphenyl ethers)in electrical and electronic equipment
GB/Z 21277-2007
Rapid screening of lead,mercury,chromium,cadmium and bromine of regulated substances in electrical and electronic equipment—X-ray fluorescence spectrometry
GB/T 23690-2009
Procedure for the declaration of materials in products of the electrotechnical and electronic industry
GB/T 26125-2011
Electrical and electronic products-Determination of six regulated substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers)
GB/T 26572-2011
Requirements of concentration limits for certain restricted substances in electrical and electronic products
GB/Z 26668-2011
Material declaration of electronic and electrical products
SN/T 2000-2006
Determination of certain hazardous substances in electrical and electronic equipment-General guidelines
SN/T 2001.1-2006
Determination of certain hazardous substances in electrical and electronic equipment-Mechanical disjointment-Part 1:General requirements
SN/T 2002-2006
Determination of certain hazardous substances in electrical and electronic equipments-Compliance assessment
SN/T 2003.1-2005
Determination of lead, mercury, cadmium, chromium and bromine in electrical and electronic equipment-Part 1:Qualitative screening by wavelength dispersive X-ray fluorescence spectrometric method
SN/T 2003.2-2006
Determination of polybrominatedbiphenyls and polybrominatedbiphenyl ether in electrical and electronic equipments-Part 2:Qualitative screening by infra-red spectrometric method
SN/T 2003.3-2006
Determination of Lead, Mercury, Chromium, Cadmium and Bromine in electrical and electronic equipment-Part 3:Quantitative screening by X-ray fluorescence spectrometric method
SN/T 2003.4-2006
Determination of lead, mercury, chromium, cadmium and electronic equipment-Part 4:Qualitative screening by energy dispersive X-ray fluorescence spectrometric method
SN/T 2003.5-2006
Determination of lead, mercury, chromium, cadmium and bromine in electrical and electronic equipment-Part 5:Quantitative screening by energy dispersive X-ray fluorescence spectrometric method
SN/T 2003.6-2010
Determination of lead, mercury, cadmium and chromium in electrical and electronic equipment-Part 6:Qualitative screening by spark discharge emission spectrometry
SN/T 2003.7-2011
Screening method of lead, mercury, cadmium, chromium and bromine in electrical and electronic equipments-Part 7:Laser induced breakdown spectroscopy
SN/T 2004.1-2005
Determination of mercury in electrical and electronic equipment-Part 1:Hydride generation-atomic fluorescence spectrometric method
SN/T 2004.2-2005
Determination of lead, cadmium and chromium in electrical and electronic equipment-Part 2:Flame atomic absorption spectrometric method
SN/T 2004.3-2005
Determination of Chromium() in electrical and electronic equipment-Part 3:1,5-Diphenylcarbohydrazide spectrophotometric method
SN/T 2004.4-2006
Determination of Lead, Cadmium, Chromiun and Mercury in electrical and electronic equipment-Part 4:Inductively coupled plasma atomic emission spectrometric method
SN/T 2004.5-2006
Determination of chromium, cadmium, mercury, lead and bromine in electrical and electronic equipment-Part 5:Inductively coupled plasma mass spectrometric method
SN/T 2004.6-2006
Determination of mercury in electrical and electronic equipment-Part 6:Cold vapor atomic absorption spectrometry
SN/T 2004.7-2006
Determination of lead, cadmium in electrical and electronic equipment-Part 7:Atomic fluorescence spectrometry
SN/T 2005.1-2005
Determination of polybromobiphenyls and polybromobiphenyl ethers in electrical and electronic equipment--Part 1:High performance liquid chromatography method
SN/T 2005.2-2005
Determination of polybromobiphenyls and polybromobiphenyl ethers in electrical and electronic equipment-Part 2:GC-MS method
SN/T 2005.3-2006
Determination of polybromobiphenyls and polybromobiphenyl in electrical and electronic equipment-Part 3:GC-FID method
SN/T 2005.4-2006
Determination of polybromobiphenyls and polybromobiphenyl ethers in electrical and electronic equipment-Part 4:GC/ECD method
SN/T 2005.5-2006
Determination of polybrominated biphenyls and polybrominated diphenyl ethers in electrical and electronic equipment-Part 5:HPLC/MS-MS method
SN/T 2591.1-2010
Determination of phthalates in electrical and electronic equipment-Part 1:Gas chromatography
SN/T 2591.2-2010
Determination of phthalates in electrical and electronic equipment-Part 2:Gas chromatography-mass spectrum
SN/T 2591.3-2010
Determination of phthalates in electrical and electronic equipment-Part 3:High performance liquid chromatography
SN/T 2592.1-2010
Determination of organotin compounds in electrical and electronic equipment-Part 1:Gas chromatography
SN/T 2592.2-2010
Determination of organotin compounds in electrical and electronic equipment-Part 2:Screening by Fourier transform infrared spectrometry
SN/T 2592.3-2010
Determination of organotin compounds in electrical and electronic equipment-Part 3:Screening by inductively coupled plasma mass spectrometry
SN/T 2592.4-2011
Determination of organotin compounds in electrical and electronic equipment-Part 4:High performance liquid chromatography-mass spectrometry
SN/T 2592.5-2011
Determination of organotin compounds in electrical and electronic equipment-Part 5:Gas chromatography-mass spectrometry
SN/T 2592.6-2011
Determination of organotin compounds in electrical and electronic equipment-Part 6:Inductively coupled plasma atomic emission spectrometry
SN/T 2593.1-2010
Determination of polycyclic aromatic hydrocarbons in electrical and electronic equipment-Part 1:High performance liquid chromatography
SN/T 2593.2-2010
Determination of polycyclic aromatic hydrocarbons in electrical and electronic equipment-Part 2:Gas chromatography-mass spectrometry
SN/T 3019.1-2011
Determination of halogen in electrical and electronic products-Part 1:Oxygen bomb combustion-Ion chromatography
 